  • Enclosed Cold Aisle Compartment for Computer Room

    Enclosed Cold Aisle Compartment for Computer Room

    Cold aisle containment systems use doors at aisle ends, ceiling panels or lids above racks, and structural frames to create enclosed zones where cold supply air flows directly to IT equipment intakes. Without containment, cold supply and hot exhaust air mix throughout the data. n is a best practice solution that separates hot and cold air streams. This method raises the temperature of the air returning to a Computer Room Air Con itioner (CRAC) unit, which allows the unit to operate more eficiently. Essentially creating a room within the aisle, the system helps keep hot and cold air separated to make existing air conditioning systems in data center and edge-of-network. Traditional open aisle data centers use perimeter PAC (precision air conditioning) or CRAC (computer room air conditioning) units to channel cold air up through a raised floor void via grilles positioned in front of the IT cabinets. This has significant disadvantages as there is no separation. ConSysTech GmbH is the right address for you! As a leading provider, we offer you a comprehensive range of first-class enclosures that ensure the efficient operation of your data center infrastructure.

    [PDF Version]
  • User optical cable dual window

    User optical cable dual window

    Dual-window optical coupler combines and splits incoming light over 1310nm and 1550nm wavelength simultaneously, and offers wide bandwidth (+/-40nm) for both windows. This type of couplers are used in systems where those two wavelength windows are required, such as WDM, FTTx. Our fiber optic couplers can be integrated into a ruggedized housing with 3 mm reinforced Kevlar fiber jackets. Contact Tech Sales for details. Lower excess loss makes device have lower signal attenuation in operation, thus reducing the power. Double-window fiber, also known as dual-window fiber, is a type of fiber optic cable designed specifically to support two different wavelengths of light. It is commonly used in applications such as communication networks, video transmission, and data transfer, as well as in sensing and monitoring. Fiberdyne Splitter/Coupler devices are bi-directional. If they are used to combine signals then they are “couplers. Splitters with a defined split ratio from one or two input fibers to 2 output fibers.

    [PDF Version]
  • Distance between air compressor pipelines and cable trays

    Distance between air compressor pipelines and cable trays

    11 Minimum Distance between process pipe surface and cable tray in parallel run shall be 300mm. 12 Cable tray system shall not be used where subject to severe physical damage. Cable trays and pipes work together to manage the flow of electricity, fluids, and gases, with cable trays primarily supporting electrical cables, and pipes. The intent of these cabling regulations is to ensure uniformity and homogeneity of the measures implemented in the ITER facility related to the protection of equipment and people against the unwanted effects of electric currents. These rules have to be respected scrupulously by the engineering. Determine minimum equipment spacing distances for midstream facilities including compressor stations, gas processing plants, and production facilities. Design and. Although BS 7671 touches on the subject of cable supports, it does not detail specifically what these support distances should be. 8 (Other Mechanical Stresses (AJ)) in that document provides requirements for cable support.

    [PDF Version]
  • How to switch between dual busbar connections

    How to switch between dual busbar connections

    Suppose there are two busbar panels, and we want to interconnect them for supplying power to a common load or switching supplies after a fixed interval. In this case, a bus coupler is used to switch the busbar power supply. In case of failure of either of the transformers, busbars, cables or their associated switchgear, a changeover option between the two will be at. So let's start with different bus-bar schemes or systems in an electrical substation. In this type, all incoming and outgoing bays such as lines, transformers, and feeders are directly connected to. A single-busbar switchgear has one main busbar that connects all incoming and outgoing circuits. The design is simple — just one main bus, circuit breakers, isolators, and protection devices.